NDT - Non Destructive Testing
ABOVE, Within, Beneath, NOTHING LEFT UNSEEN
The problem: defects don’t announce themselves
Drone inspection tells you what a structure or asset looks like. Thermography tells you where heat, moisture or electrical anomalies are hiding beneath the surface. Non-destructive testing (NDT) answers the question both leave open: what’s actually happening inside the material itself.
Through our specialist NDT network, Site Matrix extends its condition-assessment capability to weld and structural integrity, concrete scanning, and corrosion or wall-thickness surveys — coordinated the same way as our drone and thermal work: engineering-led, single point of contact, one reviewed report rather than three disconnected findings from three vendors.
NDT is delivered by accredited specialist partners under their own standards and accreditation.
The inspection that pays for itself before you've had the invoice.
Why it matters
Visual and thermal inspection can flag where to look. They can’t tell you the extent of a defect, whether a weld will hold under load, or how much wall thickness a corroded pipe has left. That’s a materials-science question, requiring certified NDT methods to answer defensibly — for insurance, compliance, handover, or peace of mind before a costly rectification decision.
OUR SERVICES
Structural & Civil Integrity
Concrete Scanning
Ground Penetrating Radar (GPR)
Concrete Condition Assessment
Covermeter survey, half-cell potential mapping, carbonation/chloride testing
● Structural steel & weld inspection
Magnetic Particle Testing (MT), Ultrasonic Testing (UT), Visual Inspection (VT)
Mechanical & Pressure Equipment Integrity
Pipeline & pressure vessel integrity
Ultrasonic thickness gauging, CUI surveys, PMI
Weld & fabrication testing
Radiographic Testing (RT), Ultrasonic Phased Array (UTPA) / Time-of-Flight Diffraction (TOFD), Penetrant Testing (PT)
Rotating & critical plant components
Eddy Current Testing, Acoustic Emission Monitoring
Access & Verification
Remote visual inspection
Drone-based Visual Testing (VT)
3D laser scanning
Laser scanning / point cloud capture
Leak & pressure testing
Hydrostatic/pneumatic testing, tracer gas leak detection
Side by Side Comparison
NDT vs. visual inspection alone
Each pillar alone gives you a view. The Site Matrix Method maps the right combination of Above, Within and Beneath to what your structure actually requires.
| Item | Visual inspection alone | NDT |
|---|---|---|
| Defect extent | Flagged, not measured | Measured and quantified |
| Weld/structural confidence | Assumed | Verified by accredited NDT specialists |
| Decision basis | Guesswork | Defensible engineering data |
How It Works
Step 1 - Scoping Call
asset, defect concerns, access constraints, standard/compliance driver
Step 2 - Method selection
matched to the question you need answered, avoiding over-scoping.
Step 3 - Specialist deployment
an accredited NDT technician scheduled and coordinated with your site/shutdown timing
Step 4 - Testing & data capture
by an accredited specialist partner
Step 5 - Engineering review
checked for consistency against drawings, specs and prior inspection history
Step 6 - Reporting & next steps
one consolidated report, plus a trade partner referral if rectification is needed
ABOVE, Within, Beneath, NOTHING LEFT UNSEEN
Engineering-led, not just coordinated
Our director holds a registered Professional Engineer (CPEng) status and sits on the National Engineering Register (NER), and that standard governs how every engagement — drone, thermal or NDT — is scoped, reviewed and reported. The technicians in our network hold the testing certifications;
Site Matrix holds the engineering accountability for how those results are interpreted and applied.
Who WE WORK WITH
Who this is for
- Commercial construction clients needing concrete scanning before penetrations, or weld verification
- Industrial / Service contractors and plant operators needing corrosion mapping, pipeline integrity checks, or shutdown-window testing
- Professional services partners — structural/civil engineers, building surveyors, project managers — needing one engineering-reviewed point of contact for NDT scopes within a wider project
Your questions answered
Frequently Asked Questions
Do you perform the testing yourselves?
No. NDT is delivered by accredited specialist partners under their own standards and accreditation. We scope the work, coordinate it with any drone or thermal inspection, and you keep one point of contact.
Which standard does testing follow?
Our NDT partners work to the standards and accreditation relevant to each method and asset type; we confirm this with you during the scoping call.
Can NDT be done without shutting down my site or equipment?
Many methods (e.g. remote visual inspection, some UT applications) can be scheduled around live operations; shutdown-dependent methods are coordinated with your maintenance window.
How is an NDT finding different from a drone or thermal finding?
NDT answers what’s happening inside a material — wall thickness, weld integrity — that visual or thermal inspection can only flag, not confirm.
What happens after testing?
A single consolidated report, engineering-reviewed, with a trade partner referral if rectification is required forms our deliverable.